- per page
CyberPower Value Pro 1600VA/960W
Product Warranty Period (Year )
Battery Warranty Period (Year )
รหัสสินค้า: CBP-VP1600ELCD
GENERAL
Phase
| Single Phase |
Form Factor
| Tower |
UPS Topology
| Line-interactive |
Energy Saving Technology
| GreenPower UPS™ Bypass Technology |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 167 ~ 295 |
Input Frequency ( Hz )
| 50 ± 5 |
| 60 ± 5 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 6.96 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| NEMA 5-15P x 1 |
|
Power Cord Length (ft.)
| 5 |
Power Cord Length (m.)
| 1.5 |
OUTPUT
Capacity (VA)
| 1600 |
Capacity (Watts)
| 960 |
On Battery Waveform
| Simulated Sine Wave |
On Battery Voltage(s) ( Vac )
| 230 ± 10% |
On Battery Frequency ( Hz )
| 50 ± 1% |
| 60 ± 1% |
Automatic Voltage Regulation (AVR)
| Single Boost, Single Buck |
Overload Protection
| Circuit Breaker |
Outlet(s) - Total
| 5 |
Outlet Type
| AS x 5 |
|
Outlet(s) - Battery & Surge Protected
| 3 |
Outlet(s) - Surge-Only Protected
| 2 |
Typical Transfer Time ( ms )
| 4 |
BATTERY
Runtime at Half Load ( min )
| 11 |
Runtime at Full Load ( min )
| 2 |
Typical Recharge Time ( Hours )
| 8 |
Start On Battery
| Yes |
User-replaceable
| No |
Battery Type
| Sealed Lead-acid |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 450 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning |
LED Indicators
| Power On |
HID Compliant USB Port(s)
| 1 |
Audible Alarms
| Battery Mode, Low Battery, Overload, UPS Fault |
Management Cable ( pcs )
| USB Cable x1 |
Ethernet Data Transmission Speed
| Up to 1Gbps |
Power Management Software
| PowerPanel Personal (Recommended) |
PHYSICAL
Enclosure Construction
| Plastic |
Color
| Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 3.9 x 11 x 14 |
Dimensions (WxHxD) (mm.)
| 100 x 281 x 355 |
Weight (lbs.)
| 22.97 |
Weight (kg.)
| 10.42 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
| 16.93 x 15.12 x 6.5 |
Dimensions (WxHxD) (mm.)
| 430 x 384 x 165 |
Weight (lbs.)
| 24.85 |
Weight (kg.)
| 11.27 |
ENVIRONMENTAL
Operating Temperature (°C)
| 0 ~ 40 |
Operating Relative Humidity (Non-condensing) ( % )
| 0 ~ 90 |
Operating Elevation ( feet/meters )
| 0-9,843 feet (0-3,000 meters) |
Storage Temperature (°F)
| -4 ~ 122 |
Storage Temperature (°C)
| -20 ~ 50 |
Storage Relative Humidity (Non-condensing) ( % )
| 0 ~ 90 |
Storage Elevation ( feet/meters )
| 0-9,843 feet (0-3,000 meters) |
Online Thermal Dissipation ( BTU/hr )
| 68 |
Audible Noise at 1.0M from Surface of Unit ( dBA )
| 50 |
CERTIFICATIONS
RoHS
| Yes |
WARRANTY
| 2 |
| 2 |
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 1000VA/900W
รหัสสินค้า: CBP-OLS1000EA
GENERAL
Phase
| Single Phase |
Form Factor
| Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 160 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~50% Load for 110 ~ 300 Vac |
| 0~60% Load for 120 ~ 300 Vac |
| 0~80% Load for 140 ~ 300 Vac |
| 0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 4.5 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| Schuko x 1 |
|
Power Cord Length (ft.)
| 5.9 |
Power Cord Length (m.)
| 1.8 |
OUTPUT
Capacity (VA)
| 1000 |
Capacity (Watts)
| 900 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 4 |
Outlet Type
| IEC C13 x 4 |
|
Outlet(s) - Battery & Surge Protected
| 4 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 15 |
Runtime at Full Load ( min )
| 5 |
Typical Recharge Time ( Hours )
| 5 |
Maximum Charging Current ( A )
| 1 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| No |
Battery Type
| Sealed Lead-acid |
Battery Quantity (Each RBP) ( pcs )
| 3 |
Battery Voltage (Each RBP) ( V )
| 36 |
Compatible Extended Battery Module (EBM)
| BPSE36V45A |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 440 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 5.94 x 8.86 x 15.51 |
Dimensions (WxHxD) (mm.)
| 151 x 225 x 394 |
Weight (lbs.)
| 28.88 |
Weight (kg.)
| 13.1 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
| 9.5 x 12.32 x 20.08 |
Dimensions (WxHxD) (mm.)
| 241 x 313 x 510 |
Weight (lbs.)
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Series RT 1000VA/900W (CBP-OLS1000ERT2Ua)
รหัสสินค้า: CBP-OLS1000ERT2Ua
GENERAL
Phase
| Single Phase |
Form Factor
| Rackmount, Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 80 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~30% Load for 80 ~ 300 Vac |
| 0~60% Load for 120 ~ 300 Vac |
| 0~80% Load for 140 ~ 300 Vac |
| 0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 4.5 |
Input Power Factor
| 0.99 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| Schuko x 1 |
|
Power Cord Length (ft.)
| 5 |
Power Cord Length (m.)
| 1.5 |
OUTPUT
Capacity (VA)
| 1000 |
Capacity (Watts)
| 900 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 8 |
Outlet Type
| IEC C13 x 8 |
|
Outlet(s) - Battery & Surge Protected
| 8 |
Outlet(s) - Critical Load (CL)
| 4 |
Outlet(s) - Non-Critical Load (NCL)
| 4 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 11 |
Runtime at Full Load ( min )
| 4 |
Typical Recharge Time ( Hours )
| 4 |
Maximum Charging Current ( A )
| 1.5 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| Yes - Qualified Personnel Only |
Battery Type
| Sealed Lead-acid |
Replacement Battery Pack
| RBP0156 |
RBP Quantity ( pcs )
| 1 |
Battery Quantity (Each RBP) ( pcs )
| 2 |
Battery Voltage (Each RBP) ( V )
| 24 |
Compatible Extended Battery Module (EBM)
| BPSE24V40ART2U |
Extended Battery Module Auto-detection
| Yes |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 363 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Types
| Color LCD |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Dry Contact (with Relay)
| Yes |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
Rackmount Rail
|
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 1500VA/1350W
รหัสสินค้า: CBP-OLS1500E
|
| Single Phase |
Form Factor
| Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 160 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~50% Load for 110 ~ 300 Vac |
| 0~60% Load for 120 ~ 300 Vac |
| 0~80% Load for 140 ~ 300 Vac |
| 0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 6.5 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| Schuko x 1 |
|
Power Cord Length (ft.)
| 5.9 |
Power Cord Length (m.)
| 1.8 |
OUTPUT
Capacity (VA)
| 1500 |
Capacity (Watts)
| 1350 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 4 |
Outlet Type
| IEC C13 x 4 |
|
Outlet(s) - Battery & Surge Protected
| 4 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 14 |
Runtime at Full Load ( min )
| 4 |
Typical Recharge Time ( Hours )
| 5 |
Maximum Charging Current ( A )
| 1 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| No |
Battery Type
| Sealed Lead-acid |
Battery Quantity (Each RBP) ( pcs )
| 3 |
Battery Voltage (Each RBP) ( V )
| 36 |
Compatible Extended Battery Module (EBM)
| BPSE36V45A |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 440 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 5.94 x 8.86 x 15.51 |
Dimensions (WxHxD) (mm.)
| 151 x 225 x 394 |
Weight (lbs.)
| 33.73 |
Weight (kg.)
| 15.3 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
| 9.5 x 12.32 x 20.08 |
Dimensions (WxHxD) (mm.)
| 241 x 313 x 510 |
Weight (lbs.
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 2000VA/1800W
รหัสสินค้า: CBP-OLS2000EA
GENERAL
Phase
| Single Phase |
Form Factor
| Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 200 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~30% Load for 80 ~ 300 Vac |
| 0~50% Load for 120 ~ 300 Vac |
| 0~75% Load for 160 ~ 300 Vac |
| 0~100% Load for 200 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 9 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| Schuko x 1 |
|
Power Cord Length (ft.)
| 5 |
Power Cord Length (m.)
| 1.5 |
OUTPUT
Capacity (VA)
| 2000 |
Capacity (Watts)
| 1800 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 4 |
Outlet Type
| IEC C13 x 4 |
|
Outlet(s) - Battery & Surge Protected
| 4 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 11.9 |
Runtime at Full Load ( min )
| 4 |
Typical Recharge Time ( Hours )
| 4 |
Maximum Charging Current ( A )
| 1.5 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| No |
Battery Type
| Sealed Lead-acid |
Compatible Extended Battery Module (EBM)
| BPSE48V40A |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 345 |
EMI/RFI Filtration
| Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Types
| Color LCD |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Dry Contact (with Relay)
| Yes |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 5.9 x 8.9 x 15.5 |
Dimensions (WxHxD) (mm.)
| 151 x 225 x 394 |
Weight (lbs.)
| 37.3 |
Weight (kg.)
| 16.9 |
ENVIRONMENTAL
Operating Temperature (°F)
| 32 ~ 104 |
Operating Temperature (°C)
| 0 ~ 40 |
Operating Relative Humidity (Non-condensing) ( % )
| 20 ~ 90 |
Operating Elevation ( feet/meter
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Series RT 1000VA/900W
รหัสสินค้า: CBP-OLS1000ERT2U
GENERAL
Phase
| Single Phase |
Form Factor
| Rackmount, Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 160 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~50% Load for 110 ~ 300 Vac |
| 0~60% Load for 120 ~ 300 Vac |
| 0~80% Load for 140 ~ 300 Vac |
| 0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 4.5 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| NEMA 5-15P x 1 |
|
Power Cord Length (ft.)
| 5 |
Power Cord Length (m.)
| 1.5 |
OUTPUT
Capacity (VA)
| 1000 |
Capacity (Watts)
| 900 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 6 |
Outlet Type
| IEC C13 x 6 |
|
Outlet(s) - Battery & Surge Protected
| 6 |
Outlet(s) - Critical Load (CL)
| 3 |
Outlet(s) - Non-Critical Load (NCL)
| 3 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 15 |
Runtime at Full Load ( min )
| 5 |
Typical Recharge Time ( Hours )
| 4 |
Maximum Charging Current ( A )
| 1 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| Yes |
Hot-swappable
| Yes |
Battery Type
| Sealed Lead-acid |
Replacement Battery Pack
| RBP0066 |
RBP Quantity ( pcs )
| 1 |
Battery Quantity (Each RBP) ( pcs )
| 3 |
Battery Voltage (Each RBP) ( V )
| 36 |
Compatible Extended Battery Module (EBM)
| BPSE36V45ART2U |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 440 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
Rackmount Rail
| Yes |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 17.24 x 3.46 x 16.93 |
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Series RT 1500VA/1350W
รหัสสินค้า: CBP-OLS1500ERT2U
GENERAL
Phase
| Single Phase |
Form Factor
| Rackmount, Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 160 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~50% Load for 110 ~ 300 Vac |
| 0~60% Load for 120 ~ 300 Vac |
| 0~80% Load for 140 ~ 300 Vac |
| 0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 6.5 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| NEMA 5-15P x 1 |
|
Power Cord Length (ft.)
| 5.9 |
Power Cord Length (m.)
| 1.8 |
OUTPUT
Capacity (VA)
| 1500 |
Capacity (Watts)
| 1350 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 6 |
Outlet Type
| IEC C13 x 6 |
|
Outlet(s) - Battery & Surge Protected
| 6 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 14 |
Runtime at Full Load ( min )
| 4 |
Typical Recharge Time ( Hours )
| 5 |
Maximum Charging Current ( A )
| 1 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| Yes |
Hot-swappable
| Yes |
Battery Type
| Sealed Lead-acid |
Replacement Battery Pack
| RBP0067 |
RBP Quantity ( pcs )
| 1 |
Battery Quantity (Each RBP) ( pcs )
| 3 |
Battery Voltage (Each RBP) ( V )
| 36 |
Compatible Extended Battery Module (EBM)
| BPSE36V45ART2U |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 440 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
Rackmount Rail
| Yes |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 17.24 x 3.46 x 16.93 |
Dimensions (WxHxD) (mm.)
| 438 x 88 x 430 |
Weight (lbs.)
| 32.19 |
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Series RT 2000VA/1800W (CBP-OLS2000ERT2Ua)
รหัสสินค้า: CBP-OLS2000ERT2Ua
GENERAL
Phase
| Single Phase |
Form Factor
| Rackmount, Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 80 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~30% Load for 80 ~ 300 Vac |
| 0~50% Load for 120 ~ 300 Vac |
| 0~75% Load for 160 ~ 300 Vac |
| 0~90% Load for 190 ~ 300 Vac |
| 0~100% Load for 200 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 9 |
Input Power Factor
| 0.99 |
Input Connector Type
| IEC C14 |
|
Detachable Power Cord Plug Type
| Schuko x 1 |
|
Power Cord Length (ft.)
| 5 |
Power Cord Length (m.)
| 1.5 |
OUTPUT
Capacity (VA)
| 2000 |
Capacity (Watts)
| 1800 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 8 |
Outlet Type
| IEC C13 x 8 |
|
Outlet(s) - Battery & Surge Protected
| 8 |
Outlet(s) - Critical Load (CL)
| 4 |
Outlet(s) - Non-Critical Load (NCL)
| 4 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 11.9 |
Runtime at Full Load ( min )
| 4 |
Typical Recharge Time ( Hours )
| 4 |
Maximum Charging Current ( A )
| 1.5 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| Yes - Qualified Personnel Only |
Battery Type
| Sealed Lead-acid |
Replacement Battery Pack
| RBP0157 |
RBP Quantity ( pcs )
| 1 |
Battery Quantity (Each RBP) ( pcs )
| 4 |
Battery Voltage (Each RBP) ( V )
| 48 |
Compatible Extended Battery Module (EBM)
| BPSE48V40ART2U |
Extended Battery Module Auto-detection
| Yes |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 363 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Types
| Color LCD |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Dry Contact (with Relay)
| Yes |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
|
Black
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 3000VA/2700W
รหัสสินค้า: CBP-OLS3000EA
|
| Single Phase |
Form Factor
| Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 190 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~50% Load for 110 ~ 300 Vac |
| 0~60% Load for 140 ~ 300 Vac |
| 0~80% Load for 160 ~ 300 Vac |
| 0~100% Load for 190 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 13.04 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C20 |
|
Detachable Power Cord Plug Type
| Schuko x 1 |
|
Power Cord Length (ft.)
| 5 |
Power Cord Length (m.)
| 1.5 |
OUTPUT
Capacity (VA)
| 3000 |
Capacity (Watts)
| 2700 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 8 |
Outlet Type
| IEC C19 x 1 |
|
| Hardwire Terminal Block x 1 | |
| IEC C13 x 6 |
|
Outlet(s) - Battery & Surge Protected
| 7 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 13.8 |
Runtime at Full Load ( min )
| 4.3 |
Typical Recharge Time ( Hours )
| 4 |
Maximum Charging Current ( A )
| 1.5 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| No |
Battery Type
| Sealed Lead-acid |
Compatible Extended Battery Module (EBM)
| BPSE72V40A |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 370 |
EMI/RFI Filtration
| Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Types
| Color LCD |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Dry Contact (with Relay)
| Yes |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
| 7.72 x 12.27 x 16.38 |
Dimensions (WxHxD) (mm.)
| 196 x 337 x 416 |
Weight (lbs.)
| 57.2 |
Weight (kg.)
| 26.0 |
ENVIRONMENTAL
Operating Temperature (°F)
| 32 ~ 104 |
Operating Temperature (°C)
| 0 ~ 40 |
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Series RT 3000VA/2700W
รหัสสินค้า: CBP-OLS3000ERT2U
GENERAL
Phase
| Single Phase |
Form Factor
| Rackmount, Tower |
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
| Yes |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage ( Vac )
| 230 ± 10% |
Input Voltage Range ( Vac )
| 190 ~ 300 |
Adjustable Voltage Range ( Vac )
| 0~50% Load for 110 ~ 300 Vac |
| 0~60% Load for 140 ~ 300 Vac |
| 0~80% Load for 160 ~ 300 Vac |
| 0~100% Load for 190 ~ 300 Vac |
Input Frequency ( Hz )
| 50 ± 10 |
| 60 ± 10 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current ( A )
| 13 |
Input Power Factor
| 0.98 |
Input Connector Type
| IEC C20 |
|
Detachable Power Cord Plug Type
| NEMA 5-15P x 1 |
|
Power Cord Length (ft.)
| 5.9 |
Power Cord Length (m.)
| 1.8 |
OUTPUT
Capacity (VA)
| 3000 |
Capacity (Watts)
| 2700 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) ( Vac )
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency ( Hz )
| 50 ± 0.5% |
| 60 ± 0.5% |
Output Frequency Setting
| Configurable |
Power Factor
| 0.9 |
ECO Mode Voltage Tolerance
| ± 15 % |
Overload Protection
| Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
| 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
| 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
| >130% Load Immediately |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<3% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass, Manual Bypass |
Outlet(s) - Total
| 9 |
Outlet Type
| IEC C19 x 1 |
|
| IEC C13 x 8 |
|
Outlet(s) - Battery & Surge Protected
| 9 |
Typical Transfer Time ( ms )
| 0 |
BATTERY
Runtime at Half Load ( min )
| 14 |
Runtime at Full Load ( min )
| 4 |
Typical Recharge Time ( Hours )
| 5 |
Maximum Charging Current ( A )
| 1 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User-replaceable
| Yes - Qualified Personnel Only |
Hot-swappable
| Yes |
Battery Type
| Sealed Lead-acid |
Replacement Battery Pack
| RBP0070 |
RBP Quantity ( pcs )
| 1 |
Battery Quantity (Each RBP) ( pcs )
| 6 |
Battery Voltage (Each RBP) ( V )
| 72 |
Compatible Extended Battery Module (EBM)
| BPSE72V45ART2U |
Max. EBM Quantity ( pcs )
| 3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
| 440 |
EMI/RFI Filtration
| Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
| 1-in, 1-out |
Phone Protection RJ11
| 1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
| Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
| 1 |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
| Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
| PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
| Metal |
Color
| Black |
Rackmount Rail
| Yes |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
|
(ราคายังไม่รวมภาษี)
สั่งซื้อสินค้า: หจก.พันธุ์ทิพย์ อินเตอร์เน็ต โซลูชั่น : 02-5480839
|













